新旧程度 | 8成新 |
---|---|
品牌 | 摩托罗拉Motorola |
型号 | R2600C |
本公司经营综测仪R2600C 二手频谱仪,质量保证,欢迎咨询洽谈。
R2600C 无线电通信综合测试仪厂家: 摩托罗拉 STANDARD V3.02.S03 CELLULAR V3.02.C03 | 选件配置 OPTIONS TRACK GENERATOR 跟踪源 GRAPHICS PRINTOUT ENHANCED SPECTRUM ANALYZER/MARKER FULL TEST SETUPS CCITT FILTER/600-OHM DVM INPUT C-MSG FILTER/600-OHM DVM INPUT IEEE-488 CABLE FAULT |
R-2600系列无线通信设备综合测试仪是一种便携式仪器,用于对频率范围为 400KHz 到 999.9999MHz 的无线通信设备进行监视或维修。该仪器可发生信号,测量调制和频率,完成一系列通常要由下列仪表才能完成的测试:射频信号发生器、频率计数器、场强计、灵敏测量接收机、AC/DC电压表、信纳比表(失真仪)、频谱仪、功率计、畸变分析仪、双工偏移发生器、扫描发生器、示波器、信令编码/解码器。
性能指标pdf
性能介绍
Operating / Display | |
Modes | AM/FM Monitor AM/FM Generate Audio Synthesizer Spectrum Analyzer Duplex Generator Sweep Generator Frequency Counter Digital Voltmeter Wattmeter Oscilloscope Signal Strength Meter SINAD/Distortion Meter |
RF Signal Generator | |
FREQUENCY | |
Range: | 400 kHz - 1 GHz |
Resolution: | 100 Hz |
Accuracy: | Refer to Accuracy of Master Oscillator |
Stabilization Time: | .1 Second |
OUTPUT | |
Range FM: | -130 dBm to 0 dBm |
Range AM: | -130 dBm to -3 dBm |
Accuracy: | ±2 dB from -0.80 dBm to -130 dBm (RF I/O PORT) |
±4 dBm for all other output levels and ports. 3 MHz to 1 GHz | |
SWEEP GENERATOR | |
Range; | 400 kHz - 1 GHz |
Resolution: | 100 Hz |
Output: | -130 dBm to 0 dBm |
Sweep Width: | Selectable up to ±5 MHz of center freq. |
Scope Coupling: | Synchronized scope trace to the sweep signal |
Accuracy: | Same as Signal Generator |
DUPLEX GENERATOR | |
Range: | 400 kHz - 1 GHz |
Resolution: | 100 Hz |
Output: | -130 dBm to 0 dBm |
Frequency Offset: | 0 MHz to ±55 MHz in 5 kHz steps |
Accuracy: | Same as Signal Generator |
SPECTRA PURITY | |
Spurious: | 35 dB within ±20 MHz of selected carrier frequency. Additional fixed spurs at an absolute level of <90 dBm at harmonic frequencies of 5 MHz. (These can affect level and modulation measurements when operated at low levels at or very near these specific frequencies.) |
Harmonics: | - 20 dBc |
FM MODULATION | |
Deviation: | 99.5 kHz |
Accuracy: | 5% of setting ±25 Hz @ 1 kHz (NB) 5% of setting ±250 Hz @ 1 kHz (WB) |
Residual FM: | 20 Hz max @ 300 Hz to 3 kHz |
External/Internal Frequency Range: | 5 Hz to 20 kHz, ±2 dB |
PHASE MODULATION (Optional) | |
Range: | 0.5 to 10 radians |
Accuracy: | ±8% at 1 KHz |
Resolution: | 1 radians (.01 below 2.00 radians) External/Internal |
Internal/External Frequency Range: | 300 to 3000 Hz |
Audio Modulation Synthesizer | |
Modulation Types: | 1 kHz tone, PRIVATE LINE, DIGITAL PRIVATE LINE, Single Tone, DTMF, Two-Tone Paging, 5/6 Tone Paging, International Select V, 20 Tone General Sequence, Tone Remote Control, External inputs from both a supplied microphone and BNC input. |
Frequency Range: | 10 Hz to 20 kHz ±1 dB |
Mod Output Level: | Programmable into 7.95 v peak |
Mod Input Impedance: | 100 ohms nominal |
1 kHz Tone Distortion: | Not to exceed 1% |
External Modulation Input: | Front panel microphone and a BNC jack are summed |
BNC Input Impedance: | 600 ohms nominal |
Microphone Supplied: | HMN1056 |
Microphone Input Conditioning: | Internal audio limiting providing IDC and pre-emphasis. |
RF Receiver | |
FREQUENCY | |
Range: | 400 kHz - 1 GHz |
Resolution: | 100 Hz |
Accuracy: | Refer to Accuracy of Master Oscillator |
Spurious Response: | 40 dB typical |
SENSITIVITY | (Above 10 MHz) |
Narrowband FM: | 2.0 uV for 10 dB EIA SINAD |
Wideband FM: | 10 uV for 10 dB EIA SINAD |
FREQUENCY ERROR METER | |
Type of Display: | Autoranging |
Resolution: | 1 Hz |
FM DEVIATION MEASUREMENT | |
Demod Range: | Up to ±5 kHz in Narrowband Up to ±75 kHz in Wideband |
Accuracy: | ±5% plus peak residual FM |
Frequency Response: | Selectable per the following: Low Pass Filters 20 kHz, 3kHz, 300Hz High Pass Filters 5 Hz, 300 Hz, 3kHz |
Demodulated Output Level: | .8 v peak per 1 kHz peak Deviation in Narrowband and per 10 kHz Deviation in Wideband |
Demodulation Output Impedance: | 100 ohms nominal |
Deviation Alarm: | Audible, set via keypad in 100 Hz increments |
AM MODULATION MEASUREMENTS | |
Demodulation Range: | 0 to 100% |
Accuracy: | ±5% for levels below 80% |
Frequency Response: | Selectable per the following: Low Pass Filters 20 kHz, 3 kHz, 300 Hz High Pass Filters 5 Hz, 300 Hz, 3 kHz |
Demodulated Output Level: | .8v peak per 10% AM modulation |
PHASE MODULATION (Optional) | |
Demod Range: | Narrowband = 1 radian Wideband = 10 radians |
Accuracy/Frequency Response: | ±5% ±0.1 rad, ± residual noise at 1 kHz, ±7.5% ±0.1 rad, ± residual noise 300 Hz to 3.5 kHz |
Metering and Measurement | |
SPECTRUM ANALYZER - SEE AND HEAR™ | |
Frequency Range: | 400 kHz to GHz |
Dispersion: | 200 kHz window - (20 kHz per div) 500 kHz window - (50 kHz per div) 1 MHz window - (100 kHz per div) 2 MHz window - (200 kHz per div) 5 MHz window - (500 kHz per div) 10 MHz window - (1 MHz per div) |
Optional: | 20 MHz window - (2 MHz per div)* 50 MHz window - (5 MHz per div)* 100 MHz window - (10 MHz per div)* * SEE AND HEARª not functional |
Dynamic Range | 60dB |
Bandwidth: | Automatically selected: 6 kHz - (100 kHz per division & below) 30 kHz - (200 kHz per division & below) |
Display Range: | +50 to -95 dBm |
Optional Markers: | Freeze, Max Hold, Peak Hold Delta or Absolute level and frequency |
SIGNAL STRENGTH INDICATOR | |
Range: | 3 MHz to 1 GHz |
Accuracy: | ±4 dB |
Sensitivity: | -100 dBm (antenna port rating) |
WATTMETER (RF I/O PORT) | |
Frequency Range: | 3 MHz to 1 GHz |
Measurement Range: | .1 watt to 125 watts |
Input Impedance: | Input Impedance: 50 ohms with maximum VSWR of 1.5:1 |
Accuracy: | ±10% |
Protection: | Over temperature alarms |
TRACKING GENERATOR | |
Frequency Range: | 400 kHz to 1 GHz |
Tracking Display Sweep Range: | 200 kHz window - (20 kHz per div) 500 kHz window - (50 kHz per div) 1 MHz window - (100 kHz per div) 2 MHz window - (200 kHz per div) 5 MHz window - (500 kHz per div) 10 MHz window - (1 MHz per div) 20 MHz window - (2 MHz per div) 50 MHz window - (5 MHz per div) |
Display Range: | 0 to -80 dBm |
CABLE FAULT (Optional) | |
Method: | Standing Wave Analysis |
Measure: | Fault distance, cable length |
Reading: | Feet and meters |
Accuracy: | 10% |
OSCILLOSCOPE | |
CRT Size: | 9 cm x 11 cm (approx. 7 inch diagonal) raster scan display with four intensity levels |
Frequency Response: | 0 to 50 kHz |
Vertical Input Ranges: | 10 mV, 20 mV, 50 mV, 100 mV, 200 mV, 500 mV, 1v, 2v, 5v, 10v per division |
Accuracy: | 5% of full scale all ranges |
Sweep Ranges: | 20 usec, 50 usec, 100 usec, 200 usec, 500 usec, 1 msec, 2 msec, 5 msec, 10 msec, 20 msec, 50 msec, 100 msec, 200 msec, 500 msec, 1 sec per division |
Trigger: | Automatic, normal and single sweep |
Optional Markers: | Delta Voltage, Delta Frequency, Delta Period |
DIGITAL VOLTMETER | |
Meter Type: | RMS |
Frequency Range: | DC plus AC of 50 Hz to 20 kHz |
DC Voltage Ranges: | 1.0V, 10.0 V, 100 V full scale |
Accuracy: | 1% full scale ±1 least significant digit |
AC Voltage Ranges: | 1.0V, 10.0 V, 70 V full scale |
Accuracy: | 5% full scale ±1 least significant digit |
Freq. Response: | 3 dB end points @ 50 Hz and 20 kHz |
FREQUENCY COUNTER | |
Frequency Range: | 5 Hz to 500 kHz plus Auto Tune |
Period Counter Range: | 5 Hz to 20 kHz |
Input Level:: | .1 v RMS minimum input level |
Resolution: | .1 Hz, 1 Hz, 10 Hz, 100 Hz and 1 kHz varying by frequency range |
Auto Tune: | Monitor mode, 20 MHz to 1 GHz unit will scan and find signals greater than -30 dBm |
Accuracy: | See TIME base |
SINAD / DISTORTION METER | |
Input Level: | .1 V to 10 V RMS |
SINAD Accuracy: | ±1 dB at 12 dB SINAD |
Distortion Range: | 1% to 20% |
Distortion Accuracy: | ±0.5% of distortion of ±10% of reading whichever is greater |
Optional: | C-Message Filter; CCITT Filter w/600 ohm switchable load |
TONE SEQUENCE DECODE | |
Modulation Types: | PRIVATE LINE, DIGITAL PRIVATE LINE, Single Tone, DTMF, Two-Tone Paging, 5/6 Tone Paging, International Select V, 20 Tone General Sequence. |
Frequency Accuracy: | ±3% from 300 Hz to 3 kHz |
Duration Accuracy: | ±12 msec for tones greater than 30 msec and 300 Hz |
TIME base | |
Standard TCXO: | Aging 1 ppm/yr, Temperature 1 ppm |
Optional OCXO: | Aging .5 ppm/yr, Temperature .05 ppm |
Power and Environmental AC: 100-130 VRMS or 200-260 VRMS@ 50 Hz to 440 Hz DC: +11 to +16 VDC Battery Option: 13.6 V, 50 minutes typical Dimensions: 21.6 x 40.7 x 43.2 cm excluding accessories, battery pack and cover Weight: 33 pounds (Basic model excluding accessory cover) Temperature: 0 C to +50 C (operating) -40 C to +85 C (storage)Interface Ports Printer / Remote Control: RS-232 DB25 (female) Color Monitor: Standard CGA, RGB, DB9 (female) RS232 PORT (Requires special cable)/Optional IEEE-488 Bi-directional port provided with capability to respond to serial (optional parallel) input command vocabulary to activate functions and return measured results. Baud rates to 9600 BPS with selectable start and parity bits. |
简单操作说明如下 按键、旋钮及指示灯 电源开关 —— 按开关ON,所有电路即通上电。如果有外接交流电,仪器自动用交流电;否则,仪器转为使用直流电。在按下ON时,仪器就完成自动选择。 ON 指示灯 —— 按下ON时此灯亮。 DC 指示灯 —— 当仪器使用直流电时,此灯亮。 游标区按键(RF,AUD及DISP) —— 确定游标在CRT三个显示区中在哪个区有效。换区后,游标停留在上次在该区所在的位置。 游标位置按键(Up,Down,Left,Right,TAB) —— 此五键用于将游标上(Up)、下(Down)、左(Left)、右 (Right)或跳某位(TAB)地移动。 HELP —— 按下可显示用于当前屏幕的帮助信息。 MEM —— 可用于内存内容的预置。 数字键(0-9) —— 用于向测试仪输入数字信息。按某数字键,则游标所在处的数字被此键代表的数代替。仪器按新输入的数工作。如果所按的数字超出允许值,则该输入被忽略,原先显示的数字不变。 +/- —— 将所显示的某一值的符号反向。 ALT —— 按此键使某一键的另一种替代功能起作用,此时,屏幕上的信息行显示ALT,再按任何其他键后,屏幕上的ALT消失。 SPF —— 显示特别功能菜单。 PRT —— 把屏幕上显示的内容打印出来。 CAL —— 命令仪器进行自校准。 P1 —— 保留用作用户选择的特别功能。现用此键来从遥控工作方式转为本地工作方式。 软按键 —— 在屏幕的下部。软按键的功能随游标所在位置的变化而变化,从而对现行游标位置提供一个菜单以指示所有可能值或输入。 SQUELCH 静噪旋钮 —— 静噪控制。顺时针旋转会增加静噪打开时的信号电平门限值。 VOLUME 音量旋钮 —— 控制喇叭音量。 BRIGHT 亮度旋钮 —— 调节屏幕亮度。CRT显示屏 这是点阵化了的9x11cm阴极射线管显示,显示内容包括数据、操作控制和指导性信息.显示方式包括数字、模拟及条状图。CRT在最后一次操作后的大约30分钟内会进入一种亮度减弱的节省状态。 插头座 RF IN/OUT —— 通过皮端口把射频输入信号接到机内的监视器,或输出机内产生的信号,在双工工作方式时,经由此端口提供组合的输入、出信号。皮端口包含射频率计的负载。在前面板上,这是唯一可以输入大功率射频的端口。 GEN OUT —— 此口与监视输入口相互独立,由它提供高电平的射频输出。请勿由此口输入大功率射频 ! ANT —— 灵敏监视接收机的输入端口,对测量空中电波很有用处。切勿由此口输入大功率射频 ! VERT/SINAD DIST/DVM COUNTER IN —— 此端口用作示波器Y轴、信纳比表、DVM(数字万用表)/计数器、畸变计、DVM以及频率计数器的输 入端。 DEMOD OUT —— 在监视或双工工作方式下,恢复解调后的音频输出端口。 EXT MOD IN —— 外部调制信号输入端口。为精确显示电平,要求输入信号为固定的峰峰值一伏信号。 MIC —— 外接话筒端口。注 意 !!! 在GEN OUT和ANT的插座中装有射频保险丝以防过载,用一个板手把BNC型插府的前端部分拧下来,就可以更换保险丝。保险丝的零件号为GG-6530277C002。保险丝应剪成0.48正负0.02英寸(12.2正负0.05mm)长,其两端应修尖以适合安装。 插座 侧面板插座RGB PORT (9 针) —— 用于外接CGA格式的彩色监视器。 RS-232 PORT (25 针) —— 用于外接打印机或其它控制器。 后面板插座 10MHz STD (BNC型插座) —— 由此端口接入或接出10MHz参考频率。输入阻抗为50欧。对输入电平的要求是70mV到1Vrms,输出电平大约为250uVrms. |
功能
MON GEN DUPLEX SWEEP GEN CELLULAR (ETACS) TRACK GENMETER
RF DISPLAY RF SCAN AC VOLTS DC VOLTS INT DIST EXT DIST SINAD PL/PERIOD COUNTER DPL DECODE DTMF DECODE FREQ COUNTER GEN SEQ DECODE 5/6 DECODE SEL V DECODE CELL AUTO CELL INBOUND CELL OUTBOUND CELL MANUALAUDIO
PL DPL DPL INVERT TONE A TONE B 5/6 TONE SELECT V (ZVEI, ZVEI MOD, ZVEI FRENCH, CCIR STD, CCIR 70ms, EEA) A/B SEQ GENERAL SEQ TONE REMOTE SAT